Tlačiť

HPLC columns, Avantor® Hichrom RPB

Dodávateľ: Avantor®
Avantor® Hichrom
HIRPB-50AMEA 0 EUR
HIRPB-50AM HI-10RPB-100SP HIRPB-250SP1 HIRPB-50P HIRPB-50AS HIRPB-50M HIRPB-35AM HI3.5RPB10CM5 HIRPB-100P3 HI-10RPB-100SP1 HIRPB-10CE5 HIRPB-10CM5 HIRPB-50AF HICHHIRPB-10CP HI-3.5RPB-150A 554-7604 554-7605 HI-10RPB-10CP3 HI-10RPB-150SP HICHHIRPB-10CE HI-3.5RPB-150M HICHHI-10RPB-10CP HIRPB-50A HIRPB-100SP1 HIRPB-150P3 HIRPB-300AF HI-3.5RPB-75AM HI-10RPB-50P3 HIRPB-250P3 HI-10RPB-75SP HIRPB-125AF HI-10RPB-50SP1 HI-10RPB-250P3 HIRPB-75SP HIRPB-50P3 HI-10RPB-10C5 HI-10RPB-10CB3 HI-3.5RPB-50M HI-3.5RPB100AF HIRPB-250P HIRPB-250M HI-3.5RPB100AM HIRPB-150SP1 HICHHI-2.5RPB-50AU HI-3.5RPB100AS HI-3.5RPB-100A HIRPB-10CB3 HI-3.5RPB-50A HIRPB-10C5 HI-10RPB-250SP1 HIRPB-50SP1 HI-3.5RPB-100M HIRPB-75SP1 HICHHI-3.5RPB-10C HI-3.5RPB150AM HIRPB-250AF HIRPB-250AM HIRPB-100P HIRPB-100M HI-3.5RPB150AS HI-10RPB-100P HIRPB-250A HI-10RPB-100A HIRPB-125A HIRPB-250AS HIRPB-100SP HI-3.5RPB-10C5 HI-10RPB-50P HI-10RPB-150P3 HI-10RPB-250P HI-10RPB-250A HIRPB-100A HI-3.5RPB150AF HI-10RPB-75P HIRPB-150P HIRPB-100AS HIRPB-150SP HIRPB-30AM HI-10RPB-150P HIRPB-150M HIRPB-10CP3 HIRPB-100AM HIRPB-250SP HI-3.5RPB-35AM HI-3.5RPB-50AS HI-10RPB-50A HI-10RPB-150SP1 HI-10RPB-50SP HIRPB-50SP HI-10RPB-150A HIRPB-100AF HI-10RPB-250SP HIRPB-75P HIRPB-150AS HIRPB-150A HIRPB-150AM HI-3.5RPB-50AM HIRPB-10C5-SK HIRPB-150AF HI-10RPB-100P3 HI-3.5RPB-50AF
HPLC columns, Avantor® Hichrom RPB
Kolony chromatografické
Avantor® Hichrom RPB is a high purity base deactivated silica which offers a unique selectivity due to the proprietary C8/C18 multi-alkyl bonding and exhaustive endcapping employed. The range includes 3,5, 5 and 10 μm phases, which are suitable for LC-MS applications and preparative separations respectively.

  • Increased productivity due to reduced analysis time
  • Decreased column length without sacrificing efficiency
  • Excellent chromatography

Avantor® Hichrom RPB is specifically designed for the reversed-phase separation of basic molecules. Residual acidic sites have been eliminated whilst monolayer coverage of the high purity silica surface has been retained to obtain optimum plate efficiency. Both octyl- and octadecylsilanes are bonded to give a material which combines the robustness of a C18 phase with the high coverage of a C8 phase. Excellent peak shapes are obtained for basic drug molecules. In addition, acids and bases can be similarly chromatographed under suitably buffered conditions.

* Use with freestanding holder HI-161 and column coupler HI-081.

Objednávacie informácie: Other dimensions columns and guard cartridges are available on request.
Order Now

Learn more

About VWR

Avantor is a vertically integrated, global supplier of discovery-to-delivery solutions for...

Viac About VWR